锅炉信息网 > 锅炉知识 > 锅炉学习

德国krom风门执行器IC40A2AR10应用程序示例

发布时间:

德国krom风门执行器IC40A2AR10应用程序示例是怎么样的?下面跟随坜合博小编来了解一下吧。

 /IC 20用于基本应用,具有三点步进控制和自动/手动模式切换,具有统计数据和错误历史,以支持服务人员外部可读位置指示器宽敞的连接室,便于安装/执行机构可直接安装在蝶阀BVG、BVA或BVH上。

  Application

  The actuators IC 20 and IC 40 are designed for all applications that require precisecontrolled rotary movement between 0'and90°They can be mounted directly onto thebutterfly valves BVG,BVA or BVH in orderto control the gas and air flow rates on gasburners.They are designed for control ratiosup to 1:10.

  An optional integrated feedback potentiometer offers the option of monitoring the currentposition of the actuator.This scan functioncan be used in automation processes.

  IC 20执行器

  IC 20 is used for basic applications.It iscontrolled by a three-point step signal.Theautomatic/manual mode changeover and theposition indicator that can be read externallyassist in the setting of the infinitely adjustableswitching cams upon commissioning.Thisenables precise settings even in the low-firerate range.

  krom执行器的应用

  执行器IC 20和IC 40设计用于需要在0°和90°之间精确控制旋转运动的所有应用。它们可以直接安装在排气阀BVG、BVA或BVH上,以控制燃气燃烧器上的气体和空气流量。它们的设计控制比为1:10。

  可选的集成反馈电位计提供了监控致动器当前位置的选项。此扫描功能可用于自动化过程。

  集成电路20

  IC 20用于基本应用。它由三点步进信号控制。自动/手动模式转换和可从外部读取的位置指示器有助于在调试时设置无限可调的切换凸轮。即使在低火速范围内,也能实现精确设置。

  IC 40执行器

  The IC 40 offers additional functions.It canbe used in continuously-controlled burnersand in step-by-step-controlled burners.Settings on the actuator IC 40 can be madeusing a PC with the parameterisation software BCSoft.Al the relevant settings for theprocess are made using the software via anoptical interface instead of with switching thecams.Various operating modes,which maybe modified,are stored in the unit.In additionthe control type(two-point signal,three-pointstep signal or continuous control),runningtimes,adjustment angles and intermediatepositions can be programmed.The actuator can also be controlled"by handusing the software.Once set,all the parameters can be savedand copied into other actuators,thus savingtime during the commissioning process.Service technicians can call up statisticaldata using BCSoft,such as hours of operation,actuating cycles and an error history.Some values can also be set to zero,forexample to record data over a specificperiod of time.

  集成电路40

  IC 40提供附加功能。它可用于连续控制燃烧器和步进控制燃烧器。可使用带有参数化软件BCSoft的PC对致动器IC 40进行设置。该过程的所有相关设置都是通过光学接口使用软件进行的,而不是通过切换膜进行的。可修改的各种操作模式存储在装置中。除控制类型(两点信号、三点步进信号或连续控制)外,可编程调节角度和中间位置。也可控制致动器“手动使用软件。一旦设置,所有参数都可以保存并复制到其他执行器中,从而在调试过程中节省时间。服务技术人员可以使用BCSoft调用统计数据,例如运行小时数、执行周期和错误历史。某些值也可以设置为零,例如记录特定时间段内的数据。”

  Application examples

  IC 20,continuous control

  For processes that require high temperatureaccuracy and low circulation in the furnaceThe actuator IC 20 is controlled by a threepoint step controller

  风门执行器应用程序示例

 IC 20执行器连续控制

  对于需要高温精度和熔炉低循环的工艺,致动器IC 20由三点步进控制器控制

 IC 40,continuous controlFor processes that require high temperatureaccuracy and low circulation in the furnace.The actuator IC 40 is controlled by a 4-20mA signal.

  The characteristic current curve can beadjusted to the process during five supportpoints.

  IC 40,连续控制对于需要高温精度和炉内低循环的过程。致动器IC 40由4-20mA信号控制。

  在五个支撑点期间,特性电流曲线可以根据过程进行调整。

 IC 40,staged controlFor processes that require a homogeneoustemperature distribution in the furnace.Theactuator IC 40 is controlled by a two-pointcontroller and operates in On/Off or High/Low intermittent mode.The actuator closeswhen the voltage supply is interrupted.Therunning time can be adjusted between 5 and25 seconds

  IC 40执行器分级控制对于需要炉内均匀均匀温度分布的工艺。致动器IC 40由两点控制器控制,并以开/关或高/低间歇模式运行。当电源中断时,执行器关闭。运行时间可在5到25秒之间调整

  IC 40,staged control with three burneroutput levelsFor processes that require a homogeneoustemperature distribution in the furnace andthree burner output levels.The actuator IC40 is controlled by a programmable control-er and works in High/Medium/Low or High/Medium/Low/Off intermittent operation.Thisallows the ignition stage to be started.Thepressure switch provides fail-safe monitoringof the maximum pilot air volume.The actuator running time can be adjusted between 5and 50(75)seconds

  IC 40,具有三个燃烧器输出水平的分级控制,用于需要炉内均匀温度分布和三个燃烧器出口水平的工艺。致动器IC40由可编程控制器控制,并在高/中/低或高/中、低/关间歇操作下工作。这允许启动点火阶段。压力开关提供最大先导空气量的故障安全监测。致动器运行时间可在5至50(75)秒之间调整

IC 40, hot air compensationFor processes in which preheated combus-tion air at a temperature of up to 450°C mustbe controlled, the actuator IC 40 is regulatedby a two-point controller to adjust the burnerfiring capacity. It runs in High/Low intermittentoperation.The running time can be adjustedbetween 5 and 25 seconds.

IC 40,热空气补偿对于必须控制温度高达450°C的预热燃烧空气的过程,致动器IC 40由两点控制器调节,以调节燃烧室容量。它以高/低间歇运行。运行时间可在5到25秒之间调整。

IC 40, staged control with online ad-justment of the burner firing capacityFor processes that require a homogeneoustemperature distribution and high temperature accuracy in the furnace.If only a low heat ouput is required, forexample to maintain the temperature in thefurnace, the burner can continue to run inintermittent operation. The adjustment angleof the valve is reduced by the analogue input(4 - 20 mA) of the actuator and the burneroutput is therefore lowered. This ensuresuniform temperature distribution even witha low burner output.The functions of the actuator IC 40 can alsobe used in the ceramics industry to correctthe lambda value or for temperature compen-sation purposes in hot air applications.

IC 40,分级控制,可在线调整燃烧器燃烧能力。对于需要炉内均匀温度分布和高温度精度的工艺。如果只需要较低的热量输出,例如为了保持炉内温度,燃烧器可以在短期内继续运行。执行器的模拟输入(4-20 mA)减小了阀门的调节角,从而降低了燃烧输出。即使在燃烧器输出较低的情况下,这也可确保温度分布均匀。致动器IC 40的功能也可用于陶瓷工业中,以校正λ值或用于热空气应用中的温度补偿。

精选推荐

  • 教你燃气热水锅炉省气的方法
    教你燃气热水锅炉省气的方法

    1、工程建筑的隔热性房子隔热保温十分关键大家都知道,再好的环保节能采暖系统假如安装在没有乃至隔热保温实际效果偏差的房子里也

  • 导热油炉投入运行前的必备条件
    导热油炉投入运行前的必备条件

    实践应用中,导热油炉在投入使用前的必备条件有:1.办理有机热载体炉登记手续,领取使用登记证。新炉安装后应经当地锅炉检验所检查验收

  • 余热导热油炉
    余热导热油炉

    本文来自热丰锅炉技术部发布,热线16649875575为烟道式余热锅炉,广泛用于化工、建材、玻璃、炭素、冶金、大型柴油机人造板加工氮肥

  • SZL15-1.6生物质蒸汽锅炉出口泰国
    SZL15-1.6生物质蒸汽锅炉出口泰国

    SZL15-1.6生物质蒸汽锅炉出口泰国执行标准:国家标准,中国制造,大国工匠精神,欧盟标准,出口产品产品遵循的标准产品制造执行的标准严格

0